{"id":1629,"date":"2026-05-08T11:00:00","date_gmt":"2026-05-08T11:00:00","guid":{"rendered":"https:\/\/entrhal-medical.de\/en\/?p=1629"},"modified":"2026-03-25T12:19:49","modified_gmt":"2026-03-25T12:19:49","slug":"medzense-lg20e-f-light-cable-tester-for-optimal-patient-safety","status":"publish","type":"post","link":"https:\/\/entrhal-medical.de\/en\/medzense-lg20e-f-light-cable-tester-for-optimal-patient-safety\/","title":{"rendered":"MedZense LG20e\/f \u2013 Light Cable Tester for Optimal Patient Safety"},"content":{"rendered":"<div class=\"container mx-auto\">\n<h2>The Problem: Poor Light Quality Compromises Visibility in the OR<\/h2>\n<\/div>\n\n<div class=\"container mx-auto\">\n<p>Minimally invasive surgery (MIS) relies heavily on the quality of medical instruments such as <strong>light cables and endoscopes<\/strong>. For surgeons, clear visibility is critical \u2013 especially during complex procedures.<\/p>\n<\/div>\n\n<div class=\"container mx-auto\">\n<p>Damaged light cables and endoscopes can significantly reduce light transmission and contrast. Without objective quality testing in the Central Sterile Services Department (CSSD\/ZSVA), devices with insufficient light quality can reach the OR daily \u2013 posing an unnoticed risk to patients.<\/p>\n<\/div>\n\n<div class=\"container mx-auto\">\n<p>Traditionally, light issues were often blamed on the light cables. Our experience shows that <strong>endoscopes frequently lose light transmission over time<\/strong>, which can affect both visibility and patient safety.<\/p>\n<\/div>\n\n<div class=\"container mx-auto\">\n<h2>The Solution: Objective Light Transmission and Spectrum Measurements<\/h2>\n<\/div>\n\n<div class=\"container mx-auto\">\n<p>The <strong>MedZense LG20-e<\/strong> is a universal solution for <strong>quick and objective testing of light cables and rigid endoscopes<\/strong> (diameters 2.7\u201310\u202fmm).<\/p>\n<\/div>\n\n<div class=\"container mx-auto\">\n<ul><li>Measures light transmission across the <strong>entire visible light spectrum<\/strong><\/li><li>Supports <strong>all major connectors and cable types<\/strong><\/li><li>Ergonomic and easy to use<\/li><li>Adjustable acceptance and rejection criteria<\/li><li>Optional <strong>ENDOYE testing<\/strong> for video laparoscopes<\/li><li>Integrated with the <strong>IQM platform<\/strong> for documentation and analysis<\/li><\/ul>\n<\/div>\n\n<div class=\"container mx-auto\">\n<p>For flexible endoscopes, the <strong>MedZense LG20-Flex<\/strong> together with the <strong>MedZense PT11<\/strong> provides the first objective, efficient way to test light transmission quality. Damaged fibers can be detected early, preventing costly damage and patient risk.<\/p>\n<\/div>\n\n<div class=\"container mx-auto\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"1024\" height=\"707\" src=\"https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/LG20-simple-1024x707.jpg\" alt=\"\" class=\"wp-image-1630\" srcset=\"https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/LG20-simple-1024x707.jpg 1024w, https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/LG20-simple-300x207.jpg 300w, https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/LG20-simple-768x530.jpg 768w, https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/LG20-simple-1536x1060.jpg 1536w, https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/LG20-simple-2048x1414.jpg 2048w, https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/LG20-simple-24x17.jpg 24w, https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/LG20-simple-36x25.jpg 36w, https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/LG20-simple-48x33.jpg 48w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption>MedZense LG20<\/figcaption><\/figure>\n<\/div>\n\n<div class=\"container mx-auto\">\n<h2>Production and Development at Entrhal Medica<\/h2>\n<\/div>\n\n<div class=\"container mx-auto\">\n<p>The MedZense product line was originally <strong>acquired from the Netherlands<\/strong>. <strong>Since then, full production and further development \u2013 including IQM software and the LG20-Flex \u2013 have been carried out at Entrhal Medical.<\/strong> This ensures the devices are fully adapted to the needs of hospitals and continuously improved based on real-world feedback.<\/p>\n<\/div>\n\n<div class=\"container mx-auto\">\n<h2>Extension: MedZense DMS \u2013 DataMatrix Scanner<\/h2>\n<\/div>\n\n<div class=\"container mx-auto\">\n<p>To complement the LG20-e\/f, we offer the <strong>MedZense DMS<\/strong>, a DataMatrix scanner for <strong>instrument identification and traceability<\/strong>.<\/p>\n<\/div>\n\n<div class=\"container mx-auto\">\n<ul><li>Fully compatible with the <strong>MedZense IQM platform<\/strong><\/li><li>Supports up to <strong>2 test devices in parallel<\/strong>, additional devices on request<\/li><li>Compact, splash-proof, and easy to clean<\/li><li>Reads <strong>small, scratched DataMatrix codes on curved or reflective surfaces<\/strong><\/li><li><strong>Plug &amp; Play<\/strong> via USB, no extra software installation required<\/li><li>Optimizes quality control, identification, and traceability of surgical instruments<\/li><\/ul>\n<\/div>\n\n<div class=\"container mx-auto\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"683\" height=\"1024\" src=\"https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/Scanner-683x1024.png\" alt=\"\" class=\"wp-image-1631\" srcset=\"https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/Scanner-683x1024.png 683w, https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/Scanner-200x300.png 200w, https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/Scanner-768x1152.png 768w, https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/Scanner-16x24.png 16w, https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/Scanner-24x36.png 24w, https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/Scanner-32x48.png 32w, https:\/\/entrhal-medical.de\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/Scanner.png 1024w\" sizes=\"(max-width: 683px) 100vw, 683px\" \/><figcaption>MedZense DataMatrixScanner<\/figcaption><\/figure>\n<\/div>\n\n<div class=\"container mx-auto\">\n<h2>Benefits for Hospitals and CSSD<\/h2>\n<\/div>\n\n<div class=\"container mx-auto\">\n<ol><li><strong>Objective quality assessment<\/strong> \u2013 quantitative measurements replace subjective judgment<\/li><li><strong>Improved visibility in the OR<\/strong> \u2013 higher light transmission and better contrast<\/li><li><strong>Enhanced patient safety<\/strong> \u2013 damaged instruments are detected early<\/li><li><strong>Cost efficiency<\/strong> \u2013 early repairs prevent expensive damage<\/li><li><strong>Flexible application<\/strong> \u2013 rigid and flexible endoscopes, all common diameters<\/li><li><strong>Workflow integration<\/strong> \u2013 IQM platform and DMS streamline quality assurance processes<\/li><\/ol>\n<\/div>\n\n<div class=\"container mx-auto\">\n<h2>Features &amp; Innovations <\/h2>\n<\/div>\n\n<div class=\"container mx-auto\">\n<ul><li><strong>ENDOYE Testing:<\/strong> Optional for ENDOEYE video laparoscopes, tracks light loss over time<\/li><li><strong>IQM System:<\/strong> USB integration for instrument-level data analysis<\/li><li><strong>Digital color loss simulation:<\/strong> Visualizes the effect of damaged fibers on light output<\/li><li><strong>MedZense DMS:<\/strong> Reliable instrument identification and traceability<\/li><li><strong>Design &amp; development at Entrhal Medical:<\/strong> robust, practical, continuously improved<\/li><\/ul>\n<\/div>\n\n<div class=\"container mx-auto\">\n<h2>Conclusion<\/h2>\n<\/div>\n\n<div class=\"container mx-auto\">\n<p>Regular testing with the <strong>MedZense LG20-e\/f<\/strong> and <strong>MedZense DMS<\/strong> prevents light cables and endoscopes with reduced light transmission from reaching the OR. The result: better visibility for surgeons, increased patient safety, fewer procedure delays, and lower repair costs.<\/p>\n<\/div>\n\n<div class=\"container mx-auto\">\n<p>Through <strong>local production, ongoing development, and smart digital integration<\/strong>, hospitals can reliably monitor the quality of their MIS instruments \u2013 a critical contribution to safety and efficiency in the operating room.<\/p>\n<\/div>\n\n<div class=\"container mx-auto\">\n<h2>Contact for product inquiries &amp; demos:<\/h2>\n<\/div>\n\n<div class=\"container mx-auto\">\n<p>Tel.: +49 2834 94 24 80<\/p>\n<\/div>\n\n<div class=\"container mx-auto\">\n<p>Email: info@entrhal-medical.de<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The Problem: Poor Light Quality Compromises Visibility in the OR Minimally invasive surgery (MIS) relies heavily on the quality of medical instruments such as light cables and endoscopes. For surgeons, clear visibility [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[1],"tags":[105,104,148,118,149,106,147,146,109,110,144,111,112],"_links":{"self":[{"href":"https:\/\/entrhal-medical.de\/en\/wp-json\/wp\/v2\/posts\/1629"}],"collection":[{"href":"https:\/\/entrhal-medical.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/entrhal-medical.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/entrhal-medical.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/entrhal-medical.de\/en\/wp-json\/wp\/v2\/comments?post=1629"}],"version-history":[{"count":1,"href":"https:\/\/entrhal-medical.de\/en\/wp-json\/wp\/v2\/posts\/1629\/revisions"}],"predecessor-version":[{"id":1632,"href":"https:\/\/entrhal-medical.de\/en\/wp-json\/wp\/v2\/posts\/1629\/revisions\/1632"}],"wp:attachment":[{"href":"https:\/\/entrhal-medical.de\/en\/wp-json\/wp\/v2\/media?parent=1629"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/entrhal-medical.de\/en\/wp-json\/wp\/v2\/categories?post=1629"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/entrhal-medical.de\/en\/wp-json\/wp\/v2\/tags?post=1629"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}